Back to top

3 Pole Breaker Timer

3 Pole Breaker Timer
3 Pole Breaker Timer

3 Pole Breaker Timer Specification

  • Resistant Feature
  • Heat and flame resistant
  • Pressure
  • Atmospheric
  • Accuracy
  • 1%
  • Usage & Applications
  • Industrial and commercial electrical panels
  • Product Type
  • 3 Pole Breaker Timer
  • Material
  • High grade thermoplastic and copper
  • Measuring Voltage Range
  • 220V - 415V AC
  • Operating Temperature
  • -10C to +55C
  • Frequency (MHz)
  • 50 Hz
  • Insulation Box
  • Yes, provided for safety and durability
  • Protection System
  • Overload and short circuit protection
  • Size
  • Standard compact
  • Color
  • Black and White
  • Dimension (L*W*H)
  • 125mm x 75mm x 60mm
  • Weight
  • Approx. 480g
 

3 Pole Breaker Timer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Day
  • Delivery Time
  • 10-30 Days
 

About 3 Pole Breaker Timer

3 Pole Breaker Timer

The Circuit Breaker Timer Instruments Is An Inexpensive,  Easy To Use Digital Micro Processor Based Breaker Timer. Its Compact And Reliable Instrument To Measure Operation Times Of All Types Of Hv And Ehv Circuit Breakers Under Charged Switch yard Conditions.

Breaker Timer Can Be Performed For All Breaker Contact Operations (Open, Close, Open Close, Close Open, And Open Close Open). Timing Results Are Recorded And Displayed On The 16X4 Back-Lit Jumbo Size Lcd Screen And Can Also Be Printed On The Built-In 2" Wide Thermal Printer With Inbuilt Memory Facility Can Store Result Up To 100 Results.



Advanced Protection and Performance

Equipped with overload and short circuit protection, the 3 Pole Breaker Timer ensures the safety and longevity of your electrical systems. Its thermal magnetic mechanism provides reliable operation under variable load and temperature. With a dielectric strength of 2kV, it withstands high-voltage scenarios while offering adjustable trip delay for process flexibility.


Robust Build and Standards Compliance

Constructed from high-grade thermoplastic and copper, the unit is robust, flame resistant, and suited for harsh environments. Fully compliant with IEC 60947-2, it promises quality and reliability for worldwide industrial and commercial applications. Its compact design and included insulation box add to safety and easy integration in panels.


Flexible Applications and Easy Installation

Ideal for industrial and commercial panels, this device supports a broad measuring voltage range (220V-415V AC) and operates flawlessly between -10C to +55C. The DIN rail mountable design ensures a straightforward installation process, and the low-maintenance construction reduces operational downtime.

FAQs of 3 Pole Breaker Timer:


Q: How is the 3 Pole Breaker Timer installed in electrical panels?

A: The breaker is designed for DIN rail mounting, facilitating quick and reliable installation into standard industrial and commercial electrical panels. The compact dimensions allow integration even in space-constrained enclosures.

Q: What type of contacts does this breaker use, and how does it benefit performance?

A: This breaker is available with SPDT or DPDT contact types, offering flexibility for various wiring schemes. High-conductivity contacts ensure efficient current flow and reduce energy losses during operation.

Q: When should the adjustable delay time be used?

A: The adjustable delay setting (0.1 to 10 seconds) is valuable for customizing protection response times to match specific equipment requirements or load characteristics, optimizing both safety and process efficiency.

Q: Where can this breaker timer be effectively applied?

A: It is suited for use in industrial and commercial settings, especially in electrical panels where accurate and reliable circuit protection is crucial. It can handle atmospheric pressures and high humidity up to 95% RH (non-condensing).

Q: What process does the trip mechanism use for protection?

A: The device employs a thermal magnetic mechanism, which responds instantly to overloads and short circuits while offering adjustable timing to mitigate nuisance tripping and prevent equipment damage.

Q: How does the insulation box enhance safety and durability?

A: The included insulation box isolates live conductors, reduces accidental contact risks, and increases overall durability, ensuring continued safe operation even in challenging conditions.

Q: What are the key benefits of using this 3 Pole Breaker Timer in your system?

A: Major benefits include precise overload and short circuit protection, high electrical accuracy (1%), heat and flame resistance, compliance with international standards, and minimal maintenance demandsmaking it a dependable solution for long-term applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Testing & Measuring Category

Turns Ratio Meter

Turns Ratio Meter

Price 4000-70000 INR / Piece

Minimum Order Quantity : 1 Piece

Frequency (MHz) : 50/60 Hz

Product Type : Turns Ratio Meter

Measuring Voltage Range : Up to 250V AC/DC

Size : Standard

Transformer Routine Test Set (Routine Tester)

Transformer Routine Test Set (Routine Tester)

Price 4000-70000 INR / Piece

Minimum Order Quantity : 1 Piece

Frequency (MHz) : 5060 Hz

Product Type : Transformer Routine Test Set (Routine Tester)

Measuring Voltage Range : 0 1000V

Size : Standard laboratory size

Route Marker

Route Marker

Price 280 INR / Piece

Minimum Order Quantity : 1 Piece

Frequency (MHz) : 50 Hertz (HZ)

Product Type : Route Marker

3 Phase TTR

3 Phase TTR

Price 70000 INR / Piece

Minimum Order Quantity : 1 Piece

Frequency (MHz) : 50 Hertz (HZ)

Product Type : Turns Ratio Tester




GST : 24ARTPD7669N1ZW trusted seller