Oil BDV Test Set About
Oil BDV Test Set
Exhibiting Innovative Testing Methods, These Machines Are In Great Demand In The Competitive Markets Of Indian And Foreign Countries. Highly Utilitarian And Durable, Testing Equipment Are Available In A Variety Of Sizes At Customer Friendly Prices.
There Is A Degradation Of Transformer Oils Or Ingress Of Moisture And It Is Necessary To Test The Insulating Oils Periodically. BDV Test Is One Of The Most Common Tests Done On All Insulating Fluids. Electrical Properties Of Insulating System Changes Due To Age And Continuous Electrical Stress.
Understanding The Requirements Of Transformer Industries, We Present A Wide Array Of Insulating Oil Testing Instrument Such As Motorized Oil BDV Test Set In Variety Of Maximum Test Voltages.
The Dielectric BDV ( Breakdown Voltage) Test Is An Important Test To Determine The Withstanding Capacity Of Any Insulating Oil Or Liquid. Oil Breakdown Tester Precise Equipment, Which Is Applied To Accurately Measure The Dielectric Breakdown Voltage Of Insulating Oil. It Consists Of The High Voltage Ac Generating Unit.
Specification
|
Resolution
|
0.1KV
|
|
Power Supply
|
AC
|
|
Voltage
|
230V
|
|
Operation
|
Manual / Motorised / Manual cum Motorised
|
|
Input Voltage
|
230V
|
|
Power
|
AC
|
|
Packaging Type
|
Wooden
|
|
Capacity
|
60KV / 80KV / 100KV
|
|
Frequency
|
50/60
|
|
Display
|
Analog / Digital
|
|
Accuracy
|
5%
|
|
Usage/Application
|
Oil Testing
|
|
Material
|
Epoxy
|
|
Brand
|
TI
|
Feature
- Input : 230V, Ac, 1 Phase.
- Output : 0- 60 / 80 / 100 KV, Ac, Motorized Output.
- Meter : High Voltage Ac Analog Or Digital Meter (Special Request), Calibrated At Primary Winding.
- Features : Confirming To Is 6792/1972 Voltage Rise Rate 2KV Per Sec. Chamber Lock Facility To Prevent From High Voltage Shock During Test.Interlock Variable Power Source To Transformer. Fuse Protection. Inspection Window At Front Side.
- Operation : Mains ON Switch, HV ON-OFF Push Button, HV Raise, Lower And Stop Switch, Auto Tripping Sensing Circuit.
- Indicator : Mains ON, HV ON & OFF Led Indicator.
- Front Panel : Operation Guide Sticker Plate.
- Housing : The Instrument Will Be Housed In A Power Coated Sheet Metal Cabinet With Based Wheel For Easy Portability.
- Accessories : Standard Length I/P Cable Approx. 3 Yard Length , Oil Cup, Go-No Go Gauge,
Precise Oil Dielectric TestingAccurately measure the dielectric breakdown voltage of transformer oil using this advanced BDV test set. With a measuring voltage range of 0-100 kV and a 2% accuracy rate, it ensures reliable results. Suitable for use in laboratories, utilities, and transformer service centers, it supports standard testing protocols as per IS 6792/IEC 60156. The included automatic timer simplifies operations, enhancing testing productivity and precision.
Robust Design, Operator SafetyBuilt with a corrosion-resistant mild steel body and glass test cell, this unit is engineered to withstand challenging environments. Operator safety is prioritized with features like a safety interlock, overvoltage and current protection, and a reliable insulation box. Its natural air-cooled design ensures stable performance even during extended testing procedures.
Convenient Operation and AccessoriesThe device is powered directly from a 230V AC mains supply, eliminating the need for batteries. It comes complete with essential accessories such as a power cord, oil test cell, insulation box, and user manual for efficient test setup. Automatic and manual modes make it flexible for diverse user requirements, while its portable compact size adds to overall convenience.
FAQ's of Oil BDV Test Set:
Q: How does the Oil BDV Test Set ensure accurate dielectric breakdown voltage measurements?
A: The test set is equipped with an adjustable electrode gap (1 mm to 5 mm) and provides a measuring voltage range of 0-100 kV with 2% accuracy. Its built-in timer and both automatic/manual operation modes help achieve consistent and reliable test results, conforming to IS 6792/IEC 60156 standards.
Q: What is the process for conducting a BDV test using this set?
A: To perform a BDV test, fill the glass test cell with 500 ml of transformer oil, adjust the electrode gap, and set the operating mode. Begin the test using the automatic or manual control, allowing the built-in timer to manage the test cycle. The result is displayed on the analog or digital meter.
Q: When and where should this Oil BDV Test Set be used?
A: This set is ideal for use in laboratories, transformer manufacturers, repair and maintenance facilities, and utilities. It should be used whenever there is a need to assess the insulating quality of transformer oil, typically during routine inspections or before commissioning electrical equipment.
Q: What are the benefits of the built-in automatic timer and safety interlock?
A: The automatic timer streamlines the testing process by ensuring precise timing, reducing human error. The safety interlock prevents accidental operation and electric shocks, enhancing overall user safety during high-voltage testing procedures.
Q: How is the electrode gap adjusted and why is this feature important?
A: The electrode gap is easily adjustable from 1 mm to 5 mm, accommodating different test standards and sample requirements. This flexibility is crucial for replicating standard test conditions and obtaining accurate, standards-compliant results.
Q: What accessories are included with the Oil BDV Test Set?
A: The set comes with all necessary accessories, including a power cord, oil test cell, user manual, and insulation box. These items simplify setup and ensure users can immediately begin testing without the need for additional equipment.