About BDV Tester Set
BDV Tester Set
Specification
| Indicator | Mains ON, HV ON & OFF LED Indicator |
| Meter | High Voltage AC Analog OR Digital |
| Output | 0-60 / 80 / 100 KV, AC, Motorized output |
| Input Voltage | 230V, AC, 1 Phase |
| Model Name/Number | M100BDV |
| Usage/Application | Transformers |
| Material | Copper |
| Brand | TI |
We are manufacturing as below Model & Range:
- M60BDV, 0-60KV, Motorized operated.
- M80BDV, 0-80KV, Motorized operated
- M100BDV, 0-100KV, motorized Operated.
Precision Testing for Transformer OilThe BDV Tester Set delivers accurate dielectric breakdown analysis for transformer oil and insulating fluids, essential for ensuring electrical system safety. With advanced microprocessor control, a programmable timer, and automatic safety cut-offs, this device meets stringent industry standards, making it ideal for laboratories, field sites, and substations.
Safety and Reliability FirstEngineered with integral safety features, including a door interlock, overvoltage trip, and insulation box, this tester ensures user protection during operation. The powder-coated unit is corrosion and impact-resistant, while passive air cooling and sturdy ABS and metal construction promote durability and performance even under frequent use.
User-Friendly Operation and MaintenanceFeaturing a clear digital LCD for results, a borosilicate glass test cup, and easy oil draining via the oil drain valve, this lightweight, portable tester streamlines the breakdown voltage testing process. The device operates efficiently between 0C to 50C and doesnt require batteries, making maintenance straightforward for users.
FAQs of BDV Tester Set:
Q: How does the BDV Tester Set measure the dielectric breakdown voltage of transformer oil?
A: This BDV Tester applies a gradually increasing voltage (up to 100 kV AC) between electrodes immersed in the oil sample, using microprocessor control to ensure accuracy. The LCD screen displays the voltage at which breakdown occurs, complying with IS 6792 and IEC 60156 standards.
Q: What are the safety features included in the BDV Tester Set?
A: Safety is prioritized with features like a door interlock to prevent accidental exposure, automatic overload and short-circuit protection, overvoltage trip, and automatic cut-off. The insulation box and robust finish further enhance operational safety.
Q: When should transformer oil be tested using this device?
A: Transformer oil should be tested regularlyideally during periodic maintenance checks or after any major repairsto monitor its dielectric strength and ensure the continued safe operation of transformers and high-voltage equipment.
Q: Where can the BDV Tester Set be used?
A: This portable tester is suitable for electricity board laboratories, substations, transformer service centers, oil testing labs, and industrial sites across India, thanks to its robust design and easy portability.
Q: What is the oil testing process with this BDV Tester Set?
A: Simply collect the oil sample in the borosilicate glass test cup, set the electrode gap (standard 2.5 mm, adjustable if necessary), close the test chamber, and start the test. The microprocessor manages voltage application and timing; results are displayed digitally. Use the oil drain valve for safe disposal after testing.
Q: What are the benefits of using this BDV Tester Set?
A: This tester offers high accuracy (1%), enhanced safety features, user-friendly programmable controls, and a clear LCD readout. Its corrosion and impact-resistant design ensure durability, while compliance with recognized standards guarantees trustworthy results.